Find the lower and upper DLT boundaries and the lower response boundary of the BOIN-ET design of Takeda, Taguri and Morita (2018). The three boundaries minimize the probability of an incorrect dose assignment under six hypotheses about the DLT and response probabilities at the current dose, and are searched on a grid of step 0.01, as in the 'boinet' package.
Usage
boin_et_boundary(
target,
target_resp,
p_saf = NULL,
p_tox = NULL,
p_saf_resp = NULL,
prior = rep(1/6, 6)
)Arguments
- target
Numeric scalar. Target DLT probability, for example 0.30.
- target_resp
Numeric scalar. Target response probability, for example 0.60.
- p_saf
Numeric scalar. Highest DLT probability deemed subtherapeutic. Defaults to
0.1 * target, the value recommended by Takeda et al. (2018), which is far below the0.6 * targetof the BOIN design.- p_tox
Numeric scalar. Lowest DLT probability deemed overly toxic. Defaults to
1.4 * target.- p_saf_resp
Numeric scalar. Highest response probability deemed subtherapeutic. Defaults to
0.6 * target_resp.- prior
Numeric vector of length 6. Prior probabilities of the six hypotheses. Defaults to
rep(1 / 6, 6), the noninformative choice of the article. The third hypothesis, under which every decision is correct, does not enter the criterion.
Value
An object of class boin_et_boundary, which is a list with
components
- lambda1
Lower DLT boundary. The dose is escalated when the observed DLT rate is at most
lambda1and the observed response rate is at mosteta1.- lambda2
Upper DLT boundary. The dose is de-escalated when the observed DLT rate is at least
lambda2.- eta1
Lower response boundary.
- prob_incorrect
The minimized probability of an incorrect decision.
- target, target_resp, p_saf, p_tox, p_saf_resp, prior
The design parameters.
Details
The grids run from p_saf to target for lambda1, from
target to p_tox for lambda2 and from
p_saf_resp to target_resp for eta1, all by 0.01. At
each grid point the probability of an incorrect decision is evaluated
with binomial probabilities for 100 patients, and the first minimum in
the order of the grids is returned. This is the search of
boinet::gridoptim(), including its expression for the fourth
hypothesis, and with the default design parameters and a target of 0.30
for the DLT and 0.60 for the response it gives the boundaries 0.14, 0.35
and 0.48 reported by Takeda et al. (2018).
References
Takeda, K., Taguri, M. and Morita, S. (2018). BOIN-ET: Bayesian optimal interval design for dose finding based on both efficacy and toxicity outcomes. Pharmaceutical Statistics, 17(4), 383-395. doi:10.1002/pst.1864
Yamaguchi, Y., Takeda, K. and Maruo, K. (2025). boinet: An R Package for Bayesian Optimal Interval Design for Dose Finding Based on Both Efficacy and Toxicity Outcomes. The R Journal, 17(2), 15-34. doi:10.32614/RJ-2025-012
Examples
bd <- boin_et_boundary(target = 0.30, target_resp = 0.60)
bd
#> BOIN-ET boundaries
#> target DLT rate : 0.3
#> target response rate : 0.6
#> p_saf / p_tox : 0.03 / 0.42
#> p_saf_resp : 0.36
#>
#> lambda1 (escalate) : 0.14
#> lambda2 (de-escalate): 0.35
#> eta1 (response) : 0.48
#> probability of an incorrect decision: 0.04703
c(bd$lambda1, bd$lambda2, bd$eta1)
#> [1] 0.14 0.35 0.48