Select the Optimal Biological Dose of BOIN-ET Trials
Source:R/boin_et_select_obd.R
boin_et_select_obd.RdSelect the optimal biological dose (OBD) from the final data of one or more trials of the BOIN-ET design, with the estimators and selection rules of the 'boinet' package.
Usage
boin_et_select_obd(
n_pts,
n_tox,
n_resp,
target,
target_resp,
p_saf = NULL,
p_tox = NULL,
p_saf_resp = NULL,
cutoff_eli = 0.95,
cutoff_eli_resp = 0.99,
p_eli = NULL,
p_eli_resp = NULL,
est_method = c("observed", "multi_iso", "fp_logistic"),
obd_method = c("max_resp", "utility_weighted", "utility_truncated_linear",
"utility_scoring"),
w1 = 0.33,
w2 = 1.09,
t_low = NULL,
t_upp = NULL,
e_low = NULL,
e_upp = NULL,
psi00 = 40,
psi11 = 60,
early_stop = NULL,
boinet_compatible = FALSE
)Arguments
- n_pts
Integer vector of patients treated at each dose, or a matrix with one row per trial.
- n_tox
DLT counts of the same shape as
n_pts.- n_resp
Response counts of the same shape as
n_pts.- target
Numeric scalar. Target DLT probability, for example 0.30.
- target_resp
Numeric scalar. Target response probability, for example 0.60.
- p_saf
Numeric scalar. Highest DLT probability deemed subtherapeutic. Defaults to
0.1 * target, the value recommended by Takeda et al. (2018), which is far below the0.6 * targetof the BOIN design.- p_tox
Numeric scalar. Lowest DLT probability deemed overly toxic. Defaults to
1.4 * target.- p_saf_resp
Numeric scalar. Highest response probability deemed subtherapeutic. Defaults to
0.6 * target_resp.- cutoff_eli
Numeric scalar. A dose is no longer admissible when the posterior probability that its DLT rate is below
p_elifalls below1 - cutoff_eli. Defaults to 0.95.- cutoff_eli_resp
Numeric scalar. A dose is no longer admissible when the posterior probability that its response rate is above
p_eli_respfalls below1 - cutoff_eli_resp. Defaults to 0.99.- p_eli
Numeric scalar or
NULL. DLT probability of the rule above. Defaults toNULL, which usestargetas the 'boinet' package does. Takeda et al. (2018) used 0.40 with a cutoff of 0.90.- p_eli_resp
Numeric scalar or
NULL. Response probability of the rule above. Defaults toNULL, which usesp_saf_respas the 'boinet' package does. Takeda et al. (2018) used 0.20 with a cutoff of 0.90.- est_method
Character scalar. Estimator of the response rates:
"observed"(the default) for the observed rates,"multi_iso"for the model-averaged unimodal isotonic regression of Lin and Yin (2017), or"fp_logistic"for the fractional polynomial logistic regression of Takeda et al. (2018), which needs the 'mfp' package.- obd_method
Character scalar. Selection rule:
"max_resp"(the default) for the admissible dose with the highest estimated response rate up to the estimated MTD, or the dose that maximizes the utility"utility_weighted","utility_truncated_linear"or"utility_scoring"among the admissible doses.- w1, w2
Numeric scalars. Weights of the weighted utility
q - w1 * p - w2 * p * (p > p_tox), wherepandqare the estimated DLT and response rates. Default to 0.33 and 1.09.- t_low, t_upp
Numeric scalars or
NULL. DLT rates between which the truncated linear utility falls from one to zero. Default top_safandp_tox.- e_low, e_upp
Numeric scalars or
NULL. Response rates between which the truncated linear utility rises from zero to one. Default top_saf_resp / 2andtarget_resp.- psi00, psi11
Numeric scalars. Scores of the scoring utility for a patient with neither DLT nor response and for a patient with both, the scores of a response without DLT and of a DLT without response being 100 and 0. Default to 40 and 60.
- early_stop
Logical vector or
NULL.TRUEfor the trials stopped early, which select no OBD. Defaults toNULL, no early stop.- boinet_compatible
Logical scalar. Apply the rule of the 'boinet' package (version 1.6.0), in which a dose excluded by its DLT data does not exclude the doses above it. Defaults to
FALSE; see Details.
Value
A list with components
- obd
Integer vector of the selected dose levels,
NAwhen no dose is selected.- reason
Character vector:
"selected","early_stop"or"no_admissible_dose".- probe
Numeric matrix of the response estimates,
NAfor the doses not tried.
Details
Only the doses with at least one patient are considered. A dose is
admissible when the posterior probability that its DLT rate is below
p_eli is at least 1 - cutoff_eli and the posterior
probability that its response rate is above p_eli_resp is at
least 1 - cutoff_eli_resp, under uniform priors, and when no
lower dose is excluded by its DLT data. When no dose is admissible, no OBD
is selected. Otherwise the DLT rates of the doses tried
are estimated by isotonic regression of the observed rates with equal
weights. Under "max_resp" the estimated MTD is the highest dose
whose estimate is as close to target as that of the closest
admissible dose, and the OBD is the admissible dose up to the MTD with the
highest response estimate. Ties go to the lowest dose. These are the
rules of boinet::obd.select(), except that in 'boinet' a dose
excluded by its DLT data does not exclude the doses above it, which can
then be selected; boinet_compatible = TRUE applies this rule, and
boin_et_simulate explains the change.
The response estimates (under "max_resp") and the utilities are
compared after rounding to ten decimals, and ties go to the lowest dose.
Doses whose utilities are equal as fractions then tie whatever the
rounding error of the platform. This happens regularly: with
"utility_scoring" and its default scores, a dose with 1 DLT and 7
responses in 15 patients and a dose with 4 DLTs and 9 responses in 15
patients both have the utility 196 / 3. 'boinet' compares the utilities
as computed, so that rounding error decides between such doses, and
versions of this package up to 2.2.0 did the same; in these trials, a
few in a thousand, the selected dose can therefore differ from that of
boinet::obd.select() and from that of earlier versions, also
with boinet_compatible = TRUE.
The model-based estimates are computed in R once for every distinct set of final data; the selection itself runs in C++.
References
Takeda, K., Taguri, M. and Morita, S. (2018). BOIN-ET: Bayesian optimal interval design for dose finding based on both efficacy and toxicity outcomes. Pharmaceutical Statistics, 17(4), 383-395. doi:10.1002/pst.1864
Yamaguchi, Y., Takeda, K., Yoshida, S. and Maruo, K. (2024). Optimal biological dose selection in dose-finding trials with model-assisted designs based on efficacy and toxicity: a simulation study. Journal of Biopharmaceutical Statistics, 34(3), 379-393. doi:10.1080/10543406.2023.2202259
Lin, R. and Yin, G. (2017). STEIN: A simple toxicity and efficacy interval design for seamless phase I/II clinical trials. Statistics in Medicine, 36(26), 4106-4120. doi:10.1002/sim.7428
Examples
# One trial: patients, DLTs and responses at four doses
boin_et_select_obd(
n_pts = c(3, 6, 12, 3), n_tox = c(0, 1, 3, 2), n_resp = c(0, 2, 7, 2),
target = 0.30, target_resp = 0.60
)
#> $obd
#> [1] 3
#>
#> $reason
#> [1] "selected"
#>
#> $probe
#> DL1 DL2 DL3 DL4
#> [1,] 0 0.3333333 0.5833333 0.6666667
#>
# The OBD under a utility
boin_et_select_obd(
n_pts = c(3, 6, 12, 3), n_tox = c(0, 1, 3, 2), n_resp = c(0, 2, 7, 2),
target = 0.30, target_resp = 0.60, obd_method = "utility_scoring"
)$obd
#> [1] 3